Issues that manual valves need to pay attention to during use
Release time:
2021-11-12
Manual valve is a control component in pipeline fluid transportation system, which is used to change the cross-section of the passage and the direction of medium flow. It has functions such as diversion, cut-off, regulation, throttling, check, diversion or overflow pressure relief. Valves used for fluid control, with nominal diameters ranging from extremely small instrument valves to industrial pipeline valves with diameters up to 10m.
Manual valve is a control component in pipeline fluid transportation system, which is used to change the cross-section of the passage and the direction of medium flow. It has functions such as diversion, cut-off, regulation, throttling, check, diversion or overflow pressure relief. Valves used for fluid control, with nominal diameters ranging from extremely small instrument valves to industrial pipeline valves with diameters up to 10m.
1、 Opening and closing of manual valves:
1. Manual valves are the most widely used valves, and their handwheels or handles are designed by ordinary manual labor, taking into account the strength of the sealing surface and the necessary closing force. Therefore, it is not possible to use a long lever or a long wrench to move the board. Some people are accustomed to using a wrench and should be strictly careful not to apply too much force, otherwise it is easy to damage the sealing surface or break the handwheel or handle.
2. When opening and closing the valve, the force should be steady and not impact. Some components of high-pressure valves with impact opening and closing have already taken into account this impact force, which cannot be equated with general valves.
3. For steam valves, before opening, they should be heated in advance and condensed water should be drained. When opening, they should be opened as slowly as possible to avoid water hammer.
4. After the valve is fully open, the handwheel should be turned back a little to tighten the threads tightly to prevent loosening and damage. For open stem valves, remember the stem position when fully open and fully closed to avoid hitting the top dead center when fully open. And facilitate the inspection of whether it is normal when fully closed. If the valve stem falls off or there are large debris embedded between the valve core seals, the position of the valve stem will change when fully closed.
5. When the pipeline is first used, there is a lot of dirt inside. The valve can be slightly opened, and the high-speed flow of the medium can be used to flush it away. Then, it should be gently closed (not quickly closed or forcefully closed to prevent residual impurities from damaging the sealing surface), and then opened again. Repeat this process multiple times to flush out the dirt and put it back into normal operation.
6. Normally open valves may have dirt sticking to their sealing surfaces. When closing, they should also be flushed clean using the above method before being officially closed.
7. If the handwheel or handle is damaged or lost, it should be immediately equipped and cannot be replaced by a flexible wrench to avoid damaging the valve stem, causing ineffective opening and closing, and resulting in accidents during production.
8. Some media, after manually closing the valve, cool down and cause the valve to shrink. The operator should close it again at an appropriate time to ensure that there are no fine seams on the sealing surface. Otherwise, the media can flow rapidly through the fine seams and easily erode the sealing surface.
9. When operating, if it is found that the operation is too laborious, the reason should be analyzed. If the packing is too tight, it can be relaxed appropriately. If the valve stem is skewed, personnel should be notified for repair. Some valves, when in the closed state, experience thermal expansion of the closing part, causing difficulty in opening; If it is necessary to open at this time, the valve cover thread can be loosened by half a turn to one turn to eliminate the stress on the valve stem, and then the handwheel can be turned.
2、 Notes:
1. High temperature valves above 200 ℃ must be tightened again due to being installed at room temperature. However, after normal use, the temperature rises, causing the bolts to expand and the gap to increase. This is called "hot tightening", and operators should pay attention to this work, otherwise leakage is likely to occur.
2. When the weather is cold and the water valve is closed for a long time, the accumulated water behind the valve should be drained. After the steam valve stops, the condensate should also be drained. The bottom of the valve is like a plug, which can be opened for drainage.
3. Non metallic valves, some are hard and brittle, while others have lower strength. When operating, the opening and closing force should not be too large, especially when using force. Also, pay attention to avoiding collisions with objects.
4. When using a new manual valve, do not press the packing too tightly to ensure no leakage, in order to avoid excessive pressure on the valve stem, accelerated wear, and difficult opening and closing.